+86-312-6775656
HZKS-3R ASTM D92 Aparat de testare a punctului de aprindere cu cupă deschisă

HZKS-3R ASTM D92 Aparat de testare a punctului de aprindere cu cupă deschisă

Aplicație Instrumentul respectă ISO 2592, ASTM D92, GB267 și GB 3536 etc. Adoptă controlul microcomputerului, care este automat. Acceptă funcționarea ecranului tactil color cu o imprimantă termică-de mare viteză pentru a imprima automat rezultatele testelor și cu funcția de auto-defecțiune. Este un ideal...
Trimite anchetă
Product Details ofHZKS-3R ASTM D92 Aparat de testare a punctului de aprindere cu cupă deschisă

 

Aplicație
The instrument complies with ISO 2592, ASTM D92, GB267 and GB 3536, etc. It adopts microcomputer  control, which is automatic. It supports color touch screen operation with high-speed thermal printer to automatically print test results and with fault self-test function. It is an ideal open cup flash point measurement instrument applied in the areas of petroleum, chemical, power, environmental protection, railway, scientific research.


Caracteristici

1. The instrument adopts color LCD large screen display, English interface, no identification keyboard, for predictable temperature, sample label, atmospheric pressure, test date and other parameters, with a prompt menu, guided input function.

2. Simulation tracking display temperature rise and experimental time function curve, with English error operation software prompt modification function, with test date, test time and other parameters prompt function

3. Automatically correct the influence of atmospheric pressure on the test and calculate the correction value

4. Differential detection, automatic correction of system deflection

5. Scan, detect, print data automatically completed, the test arm automatically rise and fall

6. Electronic ignition, forced air cooling

7. Automatic ignition without air source, improve the safety of the test


Date tehnice

1. Imput power: AC220V±10 percent , 50Hz

2. Temperature measurement range: room temperature 400 degree

Repeatability: flash point Less than or equal to 150 degree error ±3 degree

Resolution: {{0}}.1 degree ; Accuracy: 0.5 percent

3. Heating rate: comply with GB/T3536 standard

4. Ignition mode: electronic ignition, gas flame 3mm4mm;


image012

image014

image016

Request for quote_

Tag-uri populare: HZKS-3R ASTM D92 Mașină de testare a punctului de aprindere cu cupă deschisă, China, furnizori, producători, preț, de vânzare, Contor de punct de aprindere

Trimite anchetă

(0/10)